WEG Transformers USA

Manufacturer of Distribution & Power Transformers

  • About
  • Products
    • Distribution Transformers
      • Padmount Units
      • Renewable Padmount Units
      • Secondary Units
    • Power Transformers
      • Padmount Units
      • Substation Units
  • Library
    • Certifications
      • FM Certification
      • ISO Certification
      • UL Certification
    • Claim Form
    • Manuals
      • WEG Transformers USA DT Renewable Pad Manual
      • WEG Transformers USA DT Pad Manual (EN)
      • WEG Transformers USA DT Pad Manual (SPAN)
      • WEG Transformers USA DT Pad Manual (FR)
      • WEG Transformers USA DT Secondary Unit Manual
      • WEG Transformers USA Medium Power Pad Manual (EN)
      • WTU Commissioning Procedure
      • Component Replacement Procedures
        • Fan Setting
        • Liquid Temperature Gauge Replacement
    • Technical Information
      • WEG Specification Builder (DT Pad mounts)
      • Guideline C57.159-2016
      • Handling and Lifting MVT’s
      • Long Term Inspection Checklist
      • Long Term Storage Form
      • Prior to Energization Checklist
      • Prior Energization Procedure List
    • Terms & Conditions of Sales
      • WEG T&C Distribution Transformers PDF
      • WEG T&C Power Transformers PDF
    • Warranty
    • Terms & Conditions of Supply Chain
    • Literature
      • English
      • Spanish
  • Escalations
    • Distribution Transformers
      • Long Term Contracts
      • Spot Term Contracts
    • Power Transformers
  • News
  • Contact
  • Careers
  • Ethics
    • Code of Ethics
    • Code of Ethics for Suppliers
    • Policy for Preventing and Combating Corruption
    • Privacy Notice
    • Reporting Channel
  • Investor Services

Substation Units

Power Transformer: Substation Units

General Characteristics:


Phases: Three
Frequency: 50 Hz, 60Hz
Standard: IEEE, CSA, IEC
Tank Type: Substation Generator Step-up transformers, Auto Transformers, or Step-Down Transformers
Base rating: 10 MVA Base through 350 MVA Top*
High Voltage (HV): 24.94 kV through 400 kV
Low Voltage (LV): 4.16 V through 230 KV
Tertiary Voltage: 34.5 KV buried or brought out.
Tap Changer: DETC, LTC In tank or out
Windings: Copper
*Available in various design configuration to accommodate application of the transformers

Type:

Generator Step-up transformers, Auto Transformers, or Step-Down Transformers

Cooling Info:

Winding Temp Rise: 55C, 55/65C, 65C, (50C, 60C for IEC)
Cooling Class: ONAN, ONAN/ONAF, ODAF, KNAN, KNAN/KNAF
Oil: Mineral Oil, FR3 Enviro Temp

Tank:

Tank Cover: Welded, Bolted
Tank Manholes: On Cover or Tank
Tank Base: Flat bottom or Skid under base,
HV Bushing Mounting: On top cover or in Air Terminal Chamber
LV Bushing Mounting: Cover mounted or in Air Terminal Chamber
Sealed tank, Inert Air with Positive Pressure, or Conservator
Paint: Standard Gray (ASA #70 GRAY), Customizable Colors, etc.
Steel: Mild Steel

Bushings:

HV Bushing Location: IEEE segment 1-4, Cover or Side
HV Terminations: Porcelain Condenser, Solid Bulk, Solid Dielectric, Quick link
LV Bushing Location: IEEE segment 1-4, Cover or Side
LV Terminations: Porcelain Condenser, Solid Bulk, Solid Dielectric, Quick link,

Controls:

Cabinet: NEMA 3R, 4, 4X
LTC Controllers: Beckwith, TAPCON
Monitors: SEL Relays, Advance Power TTC, Eclipse, ITM 509, Dynamic Ratings
Annunciators: SEL, Seekirk

Accessories:

Arresters: Distribution Class, Intermediate Class, Station Class
Fill/ Drain Provisions: Valve, Valve w/ Sampler
Gauges: Liquid Level, Liquid Temperature, Pressure Vacuum, Winding Temperature, Additional Contacts, etc.
Pressure Relief Devices: Pressure Relief Valve, Cover Mounted Pressure Relief Device, etc.
Misc.: Rapid Rise Relay, Fill Valve, Gas Test Valve, Grounding Resistor, Ground Lugs, Schrader Valve, Ground Pads, Metering, Fiber Optic Sensors, On Line Dissolved Gas Monitor, Bushing Potential Device, etc.

WEG Transformers USA

Main Line: (636) 239-9300
Fax: (636) 239-9395

MAIN OFFICE
6350 WEG Drive
Washington, Missouri 63090

Products

DISTRIBUTION TRANSFORMERS
  Padmount Units
  Renewable Padmount Units
  Secondary Units
  Polemount Units

POWER TRANSFORMERS
  Padmount Units
  Substation Units

WEG Transformers USA

Library

TECHNICAL INFORMATION
  WEG Specification Builder (DT Pad mount)

TERMS & CONDITIONS OF SALE
  T&C Distribution Transformers
  T&C Power Transformers

WARRANTY

Privacy Policy | Terms & Conditions | © 2025 WEG USA. All rights reserved. | Website by Off-Center Design

Claim Form

Please fill out the following information and attach any relevant specifications, photos, or drawings. After submitting a Claim Form, please allow 2 – 5 business days for a WEG account specialist to review and reach out to you.

  • Customer Information

  • MM slash DD slash YYYY
  • Order Information

    Please complete at least one field.
  • Project Information

  • Claim Information - If after any intervention a claim is defined as non-warranty, WTU will charge the incurred service cost + administration fees

  • MM slash DD slash YYYY
  • Drop files here or
    Max. file size: 50 MB.
      Please attach as much information/evidence as possible so that we can fully understand the issue and find the most efficient resolution.

    Request a Quote

    Please fill out the following information and attach any relevant specifications or drawings. After submitting a request, please allow 2 – 5 business days for a WEG account specialist to send an official quotation.

    • Please include key unit requirements (KVA, HV, LV, Feed, Bushings, Etc.) for accurate pricing.
    • Max. file size: 50 MB.
    • Please include shipping location, project name, end user, etc.